1. Panicker JN, Fowler CJ, Kessler TM. Lower urinary tract dysfunction in the neurological patient: clinical assessment and management. Lancet Neurol 2015;14:720-32. PMID:
26067125
2. Taweel WA, Seyam R. Neurogenic bladder in spinal cord injury patients. Res Rep Urol 2015;7:85-99. PMID:
26090342
4. Weld KJ, Dmochowski RR. Association of level of injury and bladder behavior in patients with post-traumatic spinal cord injury. Urology 2000;55:490-4. PMID:
10736489
5. Stöhrer M, Blok B, Castro-Diaz D, Chartier-Kastler E, Del Popolo G, Kramer G, et al. EAU guidelines on neurogenic lower urinary tract dysfunction. Eur Urol 2009;56:81-8. PMID:
19403235
6. Abrams P, Andersson KE, Apostolidis A, Birder L, Bliss D, Brubaker L, et al. 6th International Consultation on Incontinence. Recommendations of the International Scientific Committee. Neurourol Urodyn 2018;37:2271-2.
7. Park YH, Ku JH, Oh SJ. Accuracy of post-void residual urine volume measurement using a portable ultrasound bladder scanner. Neurourol Urodyn 2011;30:335-8. PMID:
20658544
8. Thanagumtorn K. Accuracy of post-void residual urine volume measurement using an ultrasound bladder scanner. J Med Assoc Thai 2016;99:1061-6. PMID:
29952185
11. Novioscan. SENS-U technical documentation and user manual. Nijmegen (Netherlands): Novioscan BV; 2018.
12. Triple W Japan. DFree product specifications and user guide. Tokyo (Japan): Triple W Japan KK; 2020.
14. van Leuteren PG, Klijn AJ, de Jong TP, Dik P. SENS-U: validation of a wearable ultrasonic bladder monitor in children during urodynamic studies. J Pediatr Urol 2018;14:569.e1-569.e6. PMID:
30195717
15. van Leuteren PG, Nieuwhof-Leppink AJ, Dik P. SENS-U: clinical evaluation of a full-bladder notification—a pilot study. J Pediatr Urol 2019;15:381.e1-381.e5. PMID:
31147291
16. Cho H, Song I, Jang J, Yoo Y. A lightweight deep learning network on a system-on-chip for wearable ultrasound bladder volume measurement systems. Bioengineering (Basel) 2023;10:525. PMID:
37237594
18. Jeong HJ, Seol A, Lee S, Lim H, Lee M, Oh SJ. Portable ultrasound bladder volume measurement over entire volume range using a deep learning artificial intelligence model. Neurourol Urodyn 2025;44:1238-44. PMID:
40384598
19. Kwinten WMJ, van Leuteren PG, van Duren-van Iersel M, Dik P, Jira PE. SENS-U: continuous home monitoring of natural nocturnal bladder filling in children with nocturnal enuresis. J Pediatr Urol 2020;16:196.e1-196.e6. PMID:
32160977
20. Cai PY, Logvinenko T, Omar B, Oottamasathien S, Kurtz M, Estrada C, et al. Real-time bladder volume monitoring for pediatric patients using a commercially available wearable ultrasound device. Neurourol Urodyn 2025;44:1188-92. PMID:
40320756
21. Triple W. DFree [Internet]; San Diego (CA): DFree; 2025 [cited 2025 Nov 11]. Available from:
https://www.dfreeus.biz.
22. Edgecare Inc. EdgeFlow UW20 receives MFDS digital medical device approval [Internet]; Seoul (Korea): Edgecare Inc; 2025.
23. de Wall LL, Nieuwhof-Leppink AJ, van de Wetering EHM, Leijn E, Trompetter M, de Kort LMO, et al. Study protocol for the SENS-U trial. Trials 2022;23:648. PMID:
35964045
25. Lee K, Lee MH, Kang D, Kim S, Chang JH, Oh SJ, et al. Intelligent bladder volume monitoring for wearable ultrasound devices: enhancing accuracy through deep learning-based coarse-to-fine shape estimation. IEEE Trans Ultrason Ferroelectr Freq Control 2024;71:775-85. PMID:
38190679